无套内谢孕妇毛片免费看看丨国内女人喷潮完整视频丨精品国产av色一区二区深夜久久丨夜夜躁日日躁狠狠久久av丨情侣黄网站免费看

您好,歡迎進(jìn)入研域(上海)化學(xué)試劑有限公司網(wǎng)站!
本站熱搜:科研細(xì)胞 | 生化試劑 | 食品農(nóng)殘檢測(cè) | 動(dòng)物ELISA試劑盒 | IL-4 | IL-6 | VEGF | TNF-A
  • 公司動(dòng)態(tài)NEWS

    您當(dāng)前的位置:首頁(yè) > 公司動(dòng)態(tài) > Human Retinol binding protein(RBP )ELISA Kit

    Human Retinol binding protein(RBP )ELISA Kit

    發(fā)布時(shí)間: 2012-02-14  點(diǎn)擊次數(shù): 2594次

    Human Retinol binding protein(RBP )ELISA Kit
    Assay range:80μg/L -2000μg/L 96 determinations
    Purpose
    This kit allows for the determination of RBP concentrations in Human serum, cell culture supernates and other biological fluids

    Principle of the assay
    The kit assay Human RBP level in the sample,use Purified Human RBP antibody to coat microtiter plate wells, make solid-phase antibody, then add RBP to wells, Combined antibody which With HRP labeled goat anti-Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human RBP in the samples is then determined by comparing the O.D. of the samples to the standard curve.


    Materials provided with the kit

    1Human Retinol binding protein(RBP )ELISA Kit

    wash solution
    20ml×1bottle
    7
    Stopp Solution
    6ml×1 bottle

    2
    HRP-Conjugate reagent
    6ml×1 bottle
    8
    Standard(4000μg/L)
    0.5ml×1 bottle

    3Human Retinol binding protein(RBP )ELISA Kit

    Microelisa stripplate
    12well×8strips
    9
    Standard diluent
    1.5ml×1bottle

    4
    Sample diluent
    6ml×1 bottle
    10
    Instruction
    1

    5
    Chromogen Solution A
    6ml×1 bottle

    11
    Closure plate membrane
    2

    6
    Chromogen Solution B
    6ml×1 bottle
    12
    Sealed bags
    1
     


    Specimen requirements
    1. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
    2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

    Assay procedure
    1. Dilute and add sample:Dilute Original density Standard as follow table:
     

    2000μg/L
    5 Standard
    150μl Original density Standard+150μl Standard diluent

    1000μg/L
    4 Standard
    150μl 5 Standard+150μl Standard diluent

    500μg/L
    3 Standard

    150μl 4 Standard+150μl Standard diluent

    250μg/L
    2 Standard

    150μl 3 Standard +150μl Standard diluent

    125μg/L
    1 Standard
    150μl 2 Standard +150μl Standard diluent

     


    2.add sample:Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
    3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
    4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
    5.washing:Uncover Closure plate membrane, discard Liq
    uid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
    6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
    7.incubate:Operation with 3.
    8.washing:Operation with 5.
    9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
    10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
    11.assay:take blank well as zero , Read absorbance at 450

    nm after Adding Stop Solution and within 15min.







    Steps description

    Standard, Sample diluent
     

     

     

    Add Standard, Sample diluent, incubate for 30 min at 37℃.
     

     

     

    Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37℃.
     

     

     

    Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37℃.
     

     

     

    Add Stopp Solution
     

     

     

    Read absorbance at 450nm within 15 min
     

     

     

    calculate
     




    Calculate
    Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

    Important notes
    1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
    2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
    3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
    4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
    5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
    6. The substrate evade the light preservation.
    7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
    8. All samples, washing buffer and each kind of reject should according to infective material process.
    9. Do not mix reagents with those from other lots.

    Storage and validity
    1.Storage: 2-8℃.
    2.validity: six months.

     

產(chǎn)品中心 Products
在線客服 聯(lián)系方式

服務(wù)熱線

021-54479081
021-54461587

主站蜘蛛池模板: 日韩欧美三级在线| 亚洲欧洲综合在线| 国产suv精品一区二区| 国产草莓精品国产av片国产| 日韩中文字幕免费看| 久久精品国产99久久无毒不卡| 在线永久看片免费的视频| 久久av无码精品人妻系列试探| 无码人妻精品一区二区三区99不卡 | 午夜片神马影院福利| 日本在线 | 中文| 国产精品久久久久久爽爽爽床戏| 国产精品丝袜一区二区三区| 亚洲国产精品自在拍在线播放蜜臀| 精品人妻伦九区久久aaa片| 无尽3d精品hentai在线视频| 亚洲色无码国产精品网站可下载| 草草浮力影院| 少妇激情av一区二区三区 | 午夜精品久久久久久久喷水| 欧美国产中文| 中文字幕无线码免费人妻| 高清国产亚洲欧洲av综合一区| 国产精品久久久久久2021| 亚洲欧美在线一区中文字幕| 少妇高潮太爽了在线视频| 2019亚洲午夜无码天堂| 国产成人久久av免费看| 极品少妇扒开粉嫩小泬视频| 天堂а√在线地址中文在线| jzzijzzij亚洲成熟少妇18| 无套内谢孕妇毛片免费看看| 在线播放免费人成毛片乱码| 在线成人看片黄a免费看| 亚洲国产精品一区二区久久hs| www.xxx.国产| 精品国产一区二区三区av 性色| 国产偷人激情视频在线观看|